Snom PA1 Setup

This section covers manual setup of a Snom PA1 device for use on the Crexendo VIP platform. Note that manually registered devices are only connected to the server they are assigned to and are not part of the 100% uptime guarantee.

Provision Steps

•  Create the Extension and User in the Crexendo VIP Manager Portal. Disable the voicemail box by unchecking Enable Voicemail.

•  Set up the user for Internal Calling Only.

•  Get the device credentials by going to Users > Phones and clicking the pencil icon.

•  Get the IP address of the Snom PA1 by quickly tapping the IP/Reset button on the device. You will need the device connected to the speaker system, or headphones plugged into the line out jack.

•  Enter the IP address into a local web browser.

•  Click Identity 1 on the left side of the screen and fill in the following fields with the information retrieved in Step 3.

Edit Phone settings dialog showing Domain/Proxy, Outbound Proxy, Username, and Password fields
Display Name: (Username)
Account: (Username)
Password: (Password)
Registrar: (Domain/Proxy)
Outbound Proxy: (Outbound Proxy)
Authentication Username: (Username)

•  Press Apply.

•  Click the RTP tab and add your multicast address to the Relay Address field.

•  Click Advanced under Setup, then click SIP/RTP. Turn on Multicast Support and add the listening address for your multicast setup.

•  Click System Information and verify the Identity Status shows OK. The device is now registered and ready to use on VIP.

Snom PA1 as Multicast Listener

Use the following override to configure the PA1 to receive multicast pages:

mc_address1="224.0.1.116:5001"

Snom PA1 as Multicast Relay

The Snom PA1 can be configured to take Unicast RTP and relay it to Multicast. You can set up the Snom PA1 as an extension, call that extension, and the PA1 will broadcast the audio to its own output and to a configured multicast address.

multicast_relay_address1="224.0.1.116:5001"
Note: The Snom PA1 cannot be configured as both a Listener and a Relay at the same time.

Snom PA1+ Setup

The Snom PA1+ registers automatically via Snom Redirect (SRAPS), which means only minor tweaks are needed via overrides. Follow the steps below to register the device before applying any overrides.

Adding the PA1+ via SRAPS

SRAPS can be accessed at sraps.snom.com/phones. Log in and follow these steps:

•  From the home screen, press Phones, then click Add.

•  Enter the MAC address of the device and select CREXENDO VIP as the company.

•  Select the configuration profile based on the device type (see table below).

•  Factory reset the device. It will register and configure itself automatically on Crexendo VIP.

Device Type Configuration Profile
Snom PA1+ Snom Desk Phones
D120 Snom Desk Phones
D713 Snom Desk Phones
D717 Snom Desk Phones
D735 Snom Desk Phones
D785 Snom Desk Phones
M500 M500
M100KLE – Snom DECT MSC Devices

Auto Answer

Controls whether each identity automatically answers incoming calls. Set to "on" or "off" per identity.

# 1 = Identity 1, 2 = Identity 2, 3 = Identity 3, 4 = Identity 4
user_auto_connect1="on"
user_auto_connect2="off"
user_auto_connect3="off"
user_auto_connect4="off"

Set Codec Priority

Use the following override to set the codec priority order for the PA1+.

codec_priority_list1="pcmu,telephone-event"

Multicast Paging

Only add additional listening addresses and relay addresses if you have multiple Identities configured.

Multicast Listening

The PA1+ can listen on up to 10 zones simultaneously.

multicast_listen="on"
mc_address1="239.0.0.2:10002,name=Zone 1"
mc_address2="IP ADDRESS AND PORT,name=Zone 2"
mc_address3="IP ADDRESS AND PORT,name=Zone 3"
mc_address4="IP ADDRESS AND PORT,name=Zone 4"
mc_address5="IP ADDRESS AND PORT,name=Zone 5"
mc_address6="IP ADDRESS AND PORT,name=Zone 6"
mc_address7="IP ADDRESS AND PORT,name=Zone 7"
mc_address8="IP ADDRESS AND PORT,name=Zone 8"
mc_address9="IP ADDRESS AND PORT,name=Zone 9"
mc_address10="IP ADDRESS AND PORT,name=Zone 10"

Multicast Relay

Used for Extension-to-Multicast relay. The PA1+ supports up to 4 relay addresses, one per identity.

multicast_relay_address1="239.0.0.2:10001"
multicast_relay_address2="IP ADDRESS AND PORT"
multicast_relay_address3="IP ADDRESS AND PORT"
multicast_relay_address4="IP ADDRESS AND PORT"
Note: The Snom PA1+ cannot be configured as both a Listener and a Relay at the same time. Recommended firmware version is 10.1.198.19.

Admin Only

Unlock WebUI

This override should not be needed under normal circumstances and should not be shared with customers.

http_user="admin"
http_pass="2739"
webserver_type="http_https"

 